Can Somebody Say What Is The Provision Of Fire Under Factories Act Or Relevant Act???

Shashi (HR)
Hi!!! Seniors
I need your help.Can somebody say what is the provision of fire under factories act or relevant act??? Is there any provision for fitting number of fire extinguisher per square mitre or no. of people?Or I can simply extend pipeline?????
I eagerly waiting for reply....
Thanks and regards
Shashi S. Jha
9143188566
jayaram.nag
Hii
Hope you are from AP..In AP,AP Fire services Act 1999 clearly defines the required fire fighting equipments in any factory or Building..It depends opon the area/Height/Hazard Frequency(High/Mid/Low),,This Act almost follows NBC(National Building Code) Guidelines..Different tables are available in NBC Guidelines..
Nagaraj
9393773314
varghesemathew
Mr.Shashi,
Pl see sec.38 and the state rules under it applicable to your state.
Varghese Mathew
9961266966
asapumrao
Further to the advice by Sri Nagaraj and Sri Varghese, one has to consult the Insurance Company about the fire fighting equipment (be it fire hydrants, extinguishers etc.). Depending on the adequacy or not of the number, the Insurer will fix the premium to cover any fire accident related issues. Higher Managemnt to take a decision balancing the incidence of premium and the expenditure on the fire fighting equipment.
deepak_dorik@jbfmail.com
Dear Shashi,
You refer section 38 of The Factories Act & related State Factories Rule . Attaching herewith the TAC guideline & also Fire Load calculation information.
Thanks & Regards
Deepak B Dorik
09904002055
2 Attachment(s) [Login To View]

loginmiracle
Diff.provisions would apply to diff. factories depending on nature of manufacture, business etc. If you would give your particulars appropriate stipulations could be provided.
kumar.s.
Shashi (HR)
Thanks Mr. Kumar.This is for rubber Industry and is located in west bengal...Can you please tell me to refer some sec of some acts?????
Thanks and regards
Shashi S. Jha
loginmiracle
Dear Mr.Shashi.
I am not able to see precisely the WB Fire Safety norms for Rubber Industry. However it would suffice if you would follow BIS standards (thro' this link):
Indian Standard Code of Practice for Fire Safety of Chemical Industries (Part 1 - Rubber and Plastic) (IS : 11457 - 1985)- Buy online now at Jain Book Agency, Delhi based book store.
Also for your general updation the attached article by one Mr.Ramesh Babu could help. I would try to add some more shortly if you would need further.
kumar.s.
3 Attachment(s) [Login To View]

saswatabanerjee
Hello
This is a common topic of arguments with our clients
Sec 38 of the factories act has the relevant sections for fire safety.
The state rules will have more details.
Our act and rules are old and out dated, but we need to follow them.
There is a requirement of number of fire buckets (filled with fine dry sand and others filled with water) required to be kept. The number of fire buckets per 100 sq m of factory building is specified. Further, some states have included provision for fire extinguishers in addition to or in place of fire buckets.
There is no provision in the rules for water sprinklers.
However, the rules provide for getting exemption / waiver from them from the factory inspector. So if you follow more stringent rules laid down under ISP norms, then you can get the factory inspector to approve it
PrashantJagadale
dear Sir,
can u pls. explain how to calculate fire load in tank having 2 meter radius and containing 196000 bulk liter flammable liquid.how to calculate floor area?