Hi all at our paper plant we have installed many portable fire extinguisher.i want to make a document regarding position statusmaintenance checklist etc anyone please send the effective format. thanking you rajkumar nanda
Refilling procedures of fire extinguisher
Dear all please clear my doubt over refilling procedures of fire extinguisher . we used our 2 kg capacity abc type fire extinguisher for a training purpose in february 2013 & we refilled it on the same month. but as per the is 2190:2010 annexure d/clauses 11.4.1 and 12.3 refilling schedule for fire extinguishers & schedule for operational test i learnt that abc type extinguishers should be refilled once in 3 years. but the agency which refilled the extinguisher mentioned on the sticker pasted on the extinguisher that the next refilling date is february 2014. what should we do ? whether we will refill it in feb 2014 or feb 2016. ? thanks regards santosh
Fire audit checklist of buildings
Dear all i am in need of a fire audit checklist for conducting fire audit in office buildings. may be the checklist based on is codes nbc requirement tac requirements etc. a detailed checklist which will enable to do check on requirement vs. compliance status. if anyone having such kind of a checklist request to share. thanks in advance.
Re: help need checklist for smoke detector and manual pull station
Dear jogul warm welcome to our ehs forum. . .please find the attached fire alarm related documents & inspection checklist for your refernce. . . let you know do you need any further help. . . please wrote/ask a question clearly/correctly dont confuse our ehs members <<< u mentioned in subject u need smoke detector and manual pull station checklist/ u wrote inside checklist for this fire alarm euips>> what u need exactly. . . i hope you take positively and com forward. . . thanks & besafe raghu
Fire fighting eqpt safety
Hi all 1. i am trying replace co2 fire extinguisher trigger mechanism existing one is type like water tap with type. what i feel is that due to high pressure the user/employee may get injured please enlighten. 2. is there any norm of fire extinguisher density in an office premises. say number of fes per meter of space or something on those parameters? 3. is there a shelf life of fire fighting mechanism cylinders. if yes then is there a standard/regulation practiced in india? need your urgent help.
Fire extinguisher major incident - metal cap came out & dashed to the fatal person's neck portion
Dear all i want more information about the fire extinguisher because one major incident happened in my near to company during the training & there may be the possibility of the metal cap came out & dashed to the fatal person s neck portion. extinguisher dcp 5kg what may be the possibility of such an incident. as like 1. no proper servicing 2. metal cap lose 3. anyone playing with an extinguisher 4. pressure built up inside due to chocking. any other reason pl.provide information to avoid further incident & what is the working pressure of the extinguisher.