Dear All, Please suggest me the requirements and technique of installation of safety net in building construction. Regards, Rizwan
From India, Asansol
manishanand83
72

Dear Rizwan,
Warm Welcome to Cither Safety Forum..
First of all, I am attaching the buliding and other construction works (BOCW 1996) for your reference, you must have to read this entire document I hope your construction safety related doubt will be cleared in this entire book. We all have to follow this guidlines in India, whether construction woks is going on.

From India, Mumbai
Attached Files (Download Requires Membership)
File Type: doc BOC1996.doc (294.0 KB, 463 views)

raghuvaran chakkaravarthy
497

Dear Rizwan,
I will let you know tomorrow night with exact drawing (Just i got back from meeting need to do MOM etc..,,)
Dear Manish,
Thanks for the document its big we need time to go through it.
Again thanks for sharing a specially construction document with us. . .
keep on going. . .

From United States, Fpo
dipil
713

Dear Rizwan Have a look into the attached presentation... This will help you to choose the type of net you would like to purchase... Also the photos may be helpful to you...
From India
Attached Files (Download Requires Membership)
File Type: ppt Presentation on Safety Net.ppt (1.38 MB, 853 views)

raghuvaran chakkaravarthy
497

Safety net systems

Safety net systems consist of mesh nets, panels and connecting components. They are typically used as protection for those who work 25 feet or more above lower levels on bridges and at building construction sites. Safety net systems are rarely used for roofing work. The maximum size of each mesh net opening must not exceed 36 square inches or longer than 6 inches on a side, measured center to center. The design and performance requirements for safety net systems are in Subpart M, 1926.502(c).

Safety nets must be installed as close as possible below working surfaces, but not more than 30 feet below the surfaces. An installed net must withstand a drop test consisting of a 400-pound bag of sand 30 inches in diameter dropped from a working surface. The net must be able to withstand the impact without touching anything below it. The outer edge of a safety net must be at least 8 feet from the edge of the working surface; however, the minimum distance varies, depending on how far the net is below the working surface. See the attached extracted page/slide shows the minimum distances.

Regulation and requirements:

29 CFR 1926.105(a). Safety nets shall be provided when workplaces are more than 25 feet above the surface where the use of ladders, scaffolds, catch platforms, temporary floors, safety lines or personal fall arrest system is impractical.

29 CFR 1926.105(b). Where safety net protection is required, operations shall not be undertaken until the net is in place and has been tested.

1926.105(c)

1926.105(c)(1)

Nets shall extend 8 feet beyond the edge of the work surface where employees are exposed and shall be installed as close under the work surface as practical but in no case more than 25 feet below such work surface. Nets shall be hung with sufficient clearance to prevent user's contact with the surfaces or structures below. Such clearances shall be determined by impact load testing.

1926.105(c)(2)

It is intended that only one level of nets be required for bridge construction.

1926.105(d)

The mesh size of nets shall not exceed 6 inches by 6 inches. All new nets shall meet accepted performance standards of 17,500 foot-pounds minimum impact resistance as determined and certified by the manufacturers, and shall bear a label of proof test. Edge ropes shall provide a minimum breaking strength of 5,000 pounds.

1926.105(e)

Forged steel safety hooks or shackles shall be used to fasten the net to its supports.

1926.105(f)

Connections between net panels shall develop the full strength of the net.

Keep on touch. . .

From United States, Fpo
Attached Files (Download Requires Membership)
File Type: pdf Safety net system.pdf (149.6 KB, 467 views)

dipil
713

Dear Raghu
Thanks for sharing the write up and attachment...
My concerns are following when comes to Safety Net:
1. Whether it will give protection where Hot Works being performed. Gas Cutting molten pieces and welding spatters will damage these nets. It will be an added hazard for work. Can easily catch fire. So in areas where hot work to be performed in the higher levels whether use of safety net is advisable one. If so how we can avoid the chances of fire?
2. The fixing of safety net itself is complicated process. The one who will fix the net have to take high risk. Not always getting proper anchorage point for safety nets.
Just thought of discussing the concerns with our forum members... Come up with your views on this topic please...